Skip to main content
Unique Wood Products
Continuous hardwood handrail over a grand curved stair
Code Compliance · Stair Code Library

Every stair rule, drawn, cited, and matched to the part.

Twenty-five rules in seven sections — geometry, handrails, guards, loads, commercial and accessible, and what Houston actually enforces. Each page answers one question first, shows the three codes side by side, draws where the number is measured, and names the hardwood part that meets it.

Reflects 2021 IRC · 2021 IBC · ICC A117.1 · 2010 ADA · 2012 TAS · City of Houston Ord. 2023-907. Adoption is local and amended — confirm the edition your authority having jurisdiction has adopted.

Rules
25 pages
Residential
2021 IRC
Commercial
2021 IBC
Accessibility
A117.1 · ADA · TAS
Common paths

Start with the question you have

Six questions that account for most of the calls to the mill. Each opens the rule that answers it.

Browse by section

Seven sections, twenty-five rules

Geometry is fixed when the stringers are cut; handrails and guards are set by the railing system; loads decide how it is fastened; the commercial section is where the numbers tighten; the last section is what Houston enforces.

A residential entry stair with a turned oak newel and iron balusters meeting a commercial lobby stair with a glass guard at a shared landing01

Getting started

Which code governs the stair, and the two triggers — four risers, thirty inches — that decide whether a handrail or a guard is required at all.

Five oak treads with bullnose nosings and white risers in profile, a folding rule standing against one riser02

Stair geometry

The numbers that are fixed once the stringers are cut: riser, tread, uniformity, nosing, width, headroom, landings, winders.

Moulded oak handrail on turned white balusters rising parallel to the tread nosings of an oak stair03

Handrails

Height, graspability, continuity, extensions and clearance — the rules a wood rail is checked against on the drawing and at final.

Tall oak landing newel where the level balcony guard rail meets the sloping stair rail, with square iron balusters04

Guards

Guard height on floors and on the rake, and the sphere rules that set baluster spacing.

Base of a solid oak starting newel where it meets the first tread and the oak floor, a bullnose starting step curving around it05

Loads and structure

What the rail, the guard, the newel and the tread have to carry, and what that means for how a wood system is fastened.

Public atrium stair with rift oak treads, closed risers and round oak handrails on both sides extending onto the landings06

Commercial and accessible

Where the IBC tightens the residential numbers, what the accessible-stair section adds, and how hardwood is classified as a finish.

Architect’s desk by a window over a Houston neighbourhood, a stair section drawing and a code book weighted with oak samples07

Houston and Texas

Which editions the City of Houston, Harris County and the State of Texas actually enforce, with the ordinances and statutes they come from.

Drawn, not described

Where the number is measured

Every geometric rule in the library has a scale drawing — the nosing line, the sphere, the finger recess, the extension — so the inspector's tape and the drawing agree. Three of them.

The full tables

Everything the code says, in one place per code

The rule pages cite these tables. Open them when you need the whole chapter rather than one line.

At a glance

Residential, commercial and accessible — side by side

The fourteen numbers that decide a stair. Where the columns differ, the stricter rule usually comes from the accessible-route requirement, not the occupancy.

ItemResidential · IRCCommercial · IBCAccessible · A117.1 / ADA / TAS
Riser height7¾″ max4″ min · 7″ max4″ min · 7″ max, uniform
Tread depth (nosing to nosing)10″ min11″ min11″ min
Riser / tread variation in a flight3/8″ max3/8″ maxUniform
Open risersAllowed; reject 4″ sphere over 30″ riseOnly off the accessible route; reject 4″ sphereNot permitted
Nosing radius / bevel9/16″ radius · ½″ bevel max1/16″–9/16″½″ radius max
Nosing projection¾″–1¼″ where tread < 11″1¼″ max, uniform1½″ max
Stair width36″ min44″ min · 36″ under 50 occupantsPer IBC
Headroom6′-8″80″Per IBC
Handrails requiredOne side, 4+ risersBoth sidesBoth sides
Handrail height (nosing line)34″–38″34″–38″34″–38″
Handrail extensionsNot required12″ top · one tread bottom12″ top · one tread bottom
Guard height36″ · 34″ on open side of stair42″ · 34″–38″ where guard is the railPer IBC
Guard openings4″ sphere · 6″ triangle · 4-3/8″ at stair4″ below 36″ · 4-3/8″ to 42″ · 6″ trianglePer IBC
Handrail and guard load200 lb any direction · 50 lb/sq ft in-fill200 lb · 50 plf · 50 lb/sq ft in-fillPer IBC
One section, every dimension

The table, drawn

Riser height, tread depth and handrail height are each measured from a specific line — and a stair that is right by one convention can fail by another. This is the section every row in the table refers to.

nosing linehandrail 34″–38″plumb from the nosing lineriser 7-3/4″ max (IRC) · 7″ max (IBC)tread depth, nosing to nosing · 10″ min (IRC) · 11″ min (IBC)headroom 6′-8″ (IRC) · 80″ (IBC)plumb from the nosing line to the soffitsoffit / ceilingguard 36″ (IRC) · 42″ (IBC)4″ sphere must not passanywhere in the guard or railingNosing detailprojection 3/4″–1-1/4″radius 9/16″ max · bevel 1/2″ maxSection at 6 px to the inch. Every figure on this drawing is a row in the table above; on the flight the handrail doubles as the open-side guard at 34″–38″.
Riser height is the vertical distance between the walking surfaces of consecutive treads; tread depth is horizontal, nosing to nosing. Handrail and guard heights are measured plumb from the nosing line, headroom plumb from the nosing line to the soffit. The 4″ sphere applies everywhere in the guard, including the triangle at the tread, riser and bottom rail (6″ there under the IRC).
Sources

The documents every number here comes from

Section numbers on these pages are cited to these editions. Where a jurisdiction has adopted a different year, the section may have moved — the rule rarely has.

Code questions on a real stair

Bring the section. We check it against the part.

Riser height, tread depth, nosing radius, rail perimeter — send the stair section and the adopted code year and we confirm which stocked or custom part meets each line before you submit.

All answers →