Skip to main content
Unique Wood Products
Looking up a wide straight oak stair between two walls, a handrail on brackets on each side
Stair Code Library · Stair geometry

How wide does a stair have to be?

A residential stair must be at least 36″ wide, measured clear between finished walls or guards above the handrail height, with handrails allowed to project no more than 4½″ into that width on each side. A commercial stair is 44″ minimum, or 36″ where it serves fewer than 50 occupants, and is sized by occupant load above that. Width is measured at the tread, finish to finish, not between studs.

Reflects 2021 IRC · 2021 IBC · ICC A117.1 · 2010 ADA · 2012 TAS. Adoption is local and amended — confirm the edition your authority having jurisdiction has adopted.

Residential
36″ clear
Commercial
44″ · 36″ under 50 occupants
Handrail projection
4½″ max each side
Below the rail
31½″ one rail · 27″ two
The rule

Stair Width

A residential stair must be at least 36″ wide, measured clear between finished walls or guards above the handrail height, with handrails allowed to project no more than 4½″ into that width on each side. A commercial stair is 44″ minimum, or 36″ where it serves fewer than 50 occupants, and is sized by occupant load above that. Width is measured at the tread, finish to finish, not between studs.

Residential, commercial and accessible

ItemResidential · IRCCommercial · IBCAccessible · A117.1 / ADA / TAS
Minimum clear width36″ above the handrail44″ · 36″ where occupant load < 50Per IBC; 48″ between handrails where the stair is an accessible means of egress
Handrail projection4½″ each side4½″ each side4½″
Width below handrail height31½″ with one rail · 27″ with two——
Intermediate handrails—Every part of the width within 30″ of a rail—

Where it is measured

1½″ clear≤ 4½″ · R311.7.8.2 · IBC 1014.831½″ clear below the rail with one rail · 27″ with two36″ clear above the handrail · R311.7.1 · 44″ IBC 1011.2rail on bracketMeasured finish to finish: drywall, skirt board or the inside face of the guard — not stud to stud.IBC: every part of the width within 30″ of a rail (1014.9); 48″ between rails on an accessible means of egress (1009.3).
Width is measured finish to finish above handrail height. The rail and its bracket may take 4½″ of it on each side, leaving 31½″ below the rail with one rail and 27″ with two.

Where the 36 inches is measured

Clear width is taken at and above handrail height, between the finished surfaces on either side — drywall, skirt board or the inside face of the guard. Handrails and their brackets may project into it by up to 4½″ on each side, so a 36″ stair with a wall rail on one side has 31½″ clear below rail height, and 27″ with rails both sides. Newel posts at the top and bottom of a flight are not counted against the width of the flight.

A stair framed at 36″ between studs is under width once drywall and a ¾″ skirt board go on. Frame at 38″–39″ and finish to 36″ or better.

Commercial width is calculated

The 44″ IBC minimum is a floor. The required width is the occupant load served times 0.3″ per occupant (0.2″ in sprinklered buildings with voice alarm), so a stair serving 300 people in an unsprinklered building needs 90″. Stairs wider than 60″ need an intermediate handrail so no part of the width is more than 30″ from a rail, which on hardwood stairs means a centre rail on posts or a divided flight.

Accessible means of egress

Where a stair is part of an accessible means of egress in a building without a sprinkler system, IBC 1009.3 requires 48″ clear between the handrails so two people can carry a third. That is a width between rails, not between walls, and it adds about 9″ to the stair.

Cited

The sections, as the tables carry them

These rows are the same rows the full residential and commercial tables show, filtered to this rule. Change one there and it changes here.

Stair geometry

  • Stair widthR311.7.1

    36″ minimum clear above the handrail height. Below the handrail: 31½″ clear with one rail, 27″ with rails both sides.

    Handrails may project up to 4½″ into the required width on each side.

Handrails

  • ProjectionR311.7.8.2

    Handrails may project no more than 4½″ into the required stair width at or below handrail height, on each side.

    The projection includes the bracket. A wide moulded rail on a stand-off bracket can exceed it on a 36″ stair.

Stair geometry

  • Stair width1011.2

    44″ minimum clear. 36″ where the stair serves an occupant load under 50.

    Handrails may project up to 4½″ into the width on each side.

Handrails

  • Projection1014.8

    Handrails may project no more than 4½″ into the required width on each side.

  • Intermediate handrails1014.9

    Every part of the required stair width must be within 30″ of a handrail; on monumental stairs, rails follow the most direct path of egress travel.

    A stair wider than 60″ gets a centre rail on posts. Detail the post at the tread, not through it.

In hardwood

How the rule is met with the part

Tread width is the stair width plus what the ends do: flush into skirt boards on a closed stair, or over the open stringer with a mitred return on the open side. Stocked treads are cut to length on site for closed stringers; wider and deeper treads are milled to the section. On commercial stairs over about 54″ a single edge-glued tread is fine structurally but the intermediate-rail rule may put a post through it — detail the post at the tread, not on it.

What fails inspection

  1. 01

    Framing the stairwell at 36″ and losing 1½″ to drywall and skirts.

  2. 02

    Counting a chunky wall-rail bracket against the 4½″ projection. The projection includes the bracket; a 3½″ rail on a 2″ bracket is over.

  3. 03

    Reading 44″ as the commercial requirement without the occupant-load calculation.

Questions on this rule

Can a residential stair be 34 inches wide?
No. 36″ clear above the handrail is the minimum for a stairway. Narrower widths are permitted only for spiral stairs (26″) and for stairs to attics or crawl spaces that are not habitable.
Does the newel post reduce the stair width?
Not for code purposes. Width is measured along the flight between the walls or guards; the newel at the end of a flight sits at the landing.
How wide is a comfortable stair?
40″–42″ finished lets two people pass and a mattress turn. Most custom houses are drawn at 42″ or wider; 36″ is a minimum, not a target.
Check it against the part

Send the section. We answer with the part that meets it.

Riser, tread, nosing radius, rail perimeter, extension length — send the stair section and the adopted code year and the shop drawing comes back with each one called out.