Commercial and accessible stairs in hardwood.
IBC Chapter 10 geometry, handrails and guards; where each wood part lands in the interior-finish rules of Chapter 8; and the accessible-stair section that tightens nosings and handrail extensions. Written for the architect's stair section and the GC's submittal.
Reflects 2021 IBC · ICC A117.1. Adoption is local and amended — confirm the edition your authority having jurisdiction has adopted.
- Riser
- 4″–7″
- Tread
- 11″ min, nose to nose
- Handrails
- Both sides · 12″ extensions
- Guard
- 42″ · 4″ sphere
Five tables, from geometry to fire class
Commercial stairs in wood are routine in Type III and Type V buildings and common as finish in Type I and II — churches, offices, hospitality, multifamily common stairs. The geometry is stricter than residential, the handrails go on both sides with extensions, and the interior-finish chapter decides what class each wood part needs to be. The last table is the one most specifiers ask us about.
Stair geometry
IBC 1011 governs every stair that is not inside a one- or two-family dwelling. Dwelling units in R-2 and R-3 keep the IRC riser and tread numbers by exception.
| Item | Requirement | 2021 IBC | UWP note |
|---|---|---|---|
| Stair width | 44″ minimum clear. 36″ where the stair serves an occupant load under 50. | 1011.2 | Handrails may project up to 4½″ into the width on each side. |
| Headroom | 80″ minimum, measured vertically from the nosing line. | 1011.3 | |
| Riser height | 4″ minimum to 7″ maximum. | 1011.5.2 | Exception: R-3, dwelling units in R-2, and U accessory to R-3 — 7¾″ max riser, 10″ min tread. |
| Tread depth | 11″ minimum, measured horizontally nosing to nosing. | 1011.5.2 | Custom 1″ and thick treads are milled to the exact depth on the stair section — 11″ nose-to-nose is the usual target. |
| Winder treads | 11″ minimum at the walkline, 12″ from the narrow side, and 10″ minimum at any point within the clear width. Inside dwelling units: 10″ at the walkline and 6″ minimum. | 1011.5.3 | Winders on a commercial stair need a large radius to make 10″ at the inside corner. |
| Spiral stairways | Permitted within a dwelling unit, from a space of 250 sq ft or less serving five or fewer occupants, or from galleries and catwalks. 26″ clear width; 6¾″ tread at 12″ from the narrow edge; 9½″ maximum riser; 78″ headroom. | 1011.10 | |
| Uniformity | No more than 3/8″ between the largest and smallest riser, or tread, in a flight. | 1011.5.4 | |
| Nosing profile | Curvature or bevel not less than 1/16″ and not more than 9/16″ from the foremost projection. | 1011.5.5 | Ask for the 9/16″-radius or eased-square nosing on commercial tread orders. |
| Nosing projection | 1¼″ maximum beyond the tread below. Uniform size throughout, including the floor edge at the top of the flight. | 1011.5.5.1 · 1011.5.5.2 | A landing tread or nosing at the top of the flight must match the tread nosing — spec both from the same profile. |
| Risers | Solid, vertical or sloped under the tread above at not more than 30° from vertical. Open risers only where the stair is not on an accessible route and the opening rejects a 4″ sphere. | 1011.5.5.3 | |
| Landings | Width not less than the stair. Length in the direction of travel not less than the stair width, but need not exceed 48″ on a straight run. | 1011.6 | |
| Vertical rise per flight | 12′ maximum between floor levels or landings. | 1011.8 | |
| Walking surface | Slip-resistant and securely attached. | 1003.4 | Code language is qualitative. Specify the site-applied finish sheen and any anti-slip nosing insert with the architect. |
- Stair width1011.2
44″ minimum clear. 36″ where the stair serves an occupant load under 50.
Handrails may project up to 4½″ into the width on each side.
- Headroom1011.3
80″ minimum, measured vertically from the nosing line.
- Riser height1011.5.2
4″ minimum to 7″ maximum.
Exception: R-3, dwelling units in R-2, and U accessory to R-3 — 7¾″ max riser, 10″ min tread.
- Tread depth1011.5.2
11″ minimum, measured horizontally nosing to nosing.
Custom 1″ and thick treads are milled to the exact depth on the stair section — 11″ nose-to-nose is the usual target.
- Winder treads1011.5.3
11″ minimum at the walkline, 12″ from the narrow side, and 10″ minimum at any point within the clear width. Inside dwelling units: 10″ at the walkline and 6″ minimum.
Winders on a commercial stair need a large radius to make 10″ at the inside corner.
- Spiral stairways1011.10
Permitted within a dwelling unit, from a space of 250 sq ft or less serving five or fewer occupants, or from galleries and catwalks. 26″ clear width; 6¾″ tread at 12″ from the narrow edge; 9½″ maximum riser; 78″ headroom.
- Uniformity1011.5.4
No more than 3/8″ between the largest and smallest riser, or tread, in a flight.
- Nosing profile1011.5.5
Curvature or bevel not less than 1/16″ and not more than 9/16″ from the foremost projection.
Ask for the 9/16″-radius or eased-square nosing on commercial tread orders.
- Nosing projection1011.5.5.1 · 1011.5.5.2
1¼″ maximum beyond the tread below. Uniform size throughout, including the floor edge at the top of the flight.
A landing tread or nosing at the top of the flight must match the tread nosing — spec both from the same profile.
- Risers1011.5.5.3
Solid, vertical or sloped under the tread above at not more than 30° from vertical. Open risers only where the stair is not on an accessible route and the opening rejects a 4″ sphere.
- Landings1011.6
Width not less than the stair. Length in the direction of travel not less than the stair width, but need not exceed 48″ on a straight run.
- Vertical rise per flight1011.8
12′ maximum between floor levels or landings.
- Walking surface1003.4
Slip-resistant and securely attached.
Code language is qualitative. Specify the site-applied finish sheen and any anti-slip nosing insert with the architect.
Handrails
Commercial flights need handrails on both sides, with extensions at the top and bottom.
| Item | Requirement | 2021 IBC | UWP note |
|---|---|---|---|
| Where required | Both sides of every stair. Also both sides of ramps with a rise over 6″. | 1011.11 · 1014.1 | Exception: stairs within R-3 and dwelling units need one rail, as the IRC. |
| Height | 34″ minimum to 38″ maximum above the nosing line, uniform along the flight. | 1014.2 | |
| Graspability — Type I | Circular 1¼″–2″ outside diameter, or non-circular with a 4″–6¼″ perimeter and 2¼″ maximum cross-section. | 1014.3.1 | Match the profile table on the Handrails & Guards page to a Type I UWP rail. |
| Graspability — Type II | Perimeter over 6¼″ with the finger recess described in the residential table. | 1014.3.2 | Recognised prescriptively only in Group R-3 and inside dwelling units in R-2 (1014.3 exception). Elsewhere a Type II rail is accepted only as “equivalent graspability” by the AHJ — specify Type I on commercial and accessible stairs. |
| Continuity | Continuous without interruption by newel posts or other obstructions. | 1014.4 | Exception: a newel at a turn or landing may interrupt the rail in R-3 and dwelling units. Over-the-post fittings keep a commercial rail continuous. |
| Extensions — top | 12″ horizontal beyond the top riser, returned to a wall, guard or the walking surface. | 1014.6 | |
| Extensions — bottom | One tread depth sloped beyond the bottom riser, then returned or continued to the next flight. | 1014.6 | |
| Wall clearance | 1½″ minimum between the rail and any wall or surface. | 1014.7 | |
| Projection | Handrails may project no more than 4½″ into the required width on each side. | 1014.8 | |
| Intermediate handrails | Every part of the required stair width must be within 30″ of a handrail; on monumental stairs, rails follow the most direct path of egress travel. | 1014.9 | A stair wider than 60″ gets a centre rail on posts. Detail the post at the tread, not through it. |
- Where required1011.11 · 1014.1
Both sides of every stair. Also both sides of ramps with a rise over 6″.
Exception: stairs within R-3 and dwelling units need one rail, as the IRC.
- Height1014.2
34″ minimum to 38″ maximum above the nosing line, uniform along the flight.
- Graspability — Type I1014.3.1
Circular 1¼″–2″ outside diameter, or non-circular with a 4″–6¼″ perimeter and 2¼″ maximum cross-section.
Match the profile table on the Handrails & Guards page to a Type I UWP rail.
- Graspability — Type II1014.3.2
Perimeter over 6¼″ with the finger recess described in the residential table.
Recognised prescriptively only in Group R-3 and inside dwelling units in R-2 (1014.3 exception). Elsewhere a Type II rail is accepted only as “equivalent graspability” by the AHJ — specify Type I on commercial and accessible stairs.
- Continuity1014.4
Continuous without interruption by newel posts or other obstructions.
Exception: a newel at a turn or landing may interrupt the rail in R-3 and dwelling units. Over-the-post fittings keep a commercial rail continuous.
- Extensions — top1014.6
12″ horizontal beyond the top riser, returned to a wall, guard or the walking surface.
- Extensions — bottom1014.6
One tread depth sloped beyond the bottom riser, then returned or continued to the next flight.
- Wall clearance1014.7
1½″ minimum between the rail and any wall or surface.
- Projection1014.8
Handrails may project no more than 4½″ into the required width on each side.
- Intermediate handrails1014.9
Every part of the required stair width must be within 30″ of a handrail; on monumental stairs, rails follow the most direct path of egress travel.
A stair wider than 60″ gets a centre rail on posts. Detail the post at the tread, not through it.
Guards
| Item | Requirement | 2021 IBC | UWP note |
|---|---|---|---|
| Where required | Open sides of walking surfaces more than 30″ above the floor or grade below, within 36″ horizontally. | 1015.2 | |
| Height | 42″ minimum above the walking surface or nosing line. | 1015.3 | Exceptions: 36″ in R-3 and R-2 dwelling units; 34″–38″ where the top of the guard is the stair handrail. |
| Openings below 36″ | Must not pass a 4″ sphere. | 1015.4 | |
| Openings 36″ to 42″ | Must not pass a 4-3/8″ sphere. | 1015.4 exc. 1 | |
| Stair triangle | The tread / riser / bottom-rail triangle may not pass a 6″ sphere. | 1015.4 exc. 2 |
- Where required1015.2
Open sides of walking surfaces more than 30″ above the floor or grade below, within 36″ horizontally.
- Height1015.3
42″ minimum above the walking surface or nosing line.
Exceptions: 36″ in R-3 and R-2 dwelling units; 34″–38″ where the top of the guard is the stair handrail.
- Openings below 36″1015.4
Must not pass a 4″ sphere.
- Openings 36″ to 42″1015.4 exc. 1
Must not pass a 4-3/8″ sphere.
- Stair triangle1015.4 exc. 2
The tread / riser / bottom-rail triangle may not pass a 6″ sphere.
Loads
IBC 1607 sets the design loads. Guards and their anchorage on commercial work are usually a delegated-design item stamped by the fabricator’s engineer.
| Item | Requirement | 2021 IBC | UWP note |
|---|---|---|---|
| Stair live load | 100 psf uniformly distributed; 40 psf in one- and two-family dwellings. | Table 1607.1 | |
| Tread concentrated load | 300 lb on an area of 4 sq in, where it produces greater stress than the uniform load. | Table 1607.1, note | |
| Handrail and guard — uniform | 50 plf applied in any direction along the handrail or top rail. Not required for one- and two-family dwellings. | 1607.9.1 | Sizes the posts on long balcony runs. Not applied concurrently with the 200 lb. |
| Handrail and guard — concentrated | 200 lb applied in any direction at any point along the handrail or top rail. | 1607.9.1.1 | |
| In-fill | Balusters, panels and other in-fill: 50 lb horizontal on an area not exceeding 12″ × 12″, including openings and the space between rails, not concurrent with the top-rail loads. | 1607.9.1.2 |
- Stair live loadTable 1607.1
100 psf uniformly distributed; 40 psf in one- and two-family dwellings.
- Tread concentrated loadTable 1607.1, note
300 lb on an area of 4 sq in, where it produces greater stress than the uniform load.
- Handrail and guard — uniform1607.9.1
50 plf applied in any direction along the handrail or top rail. Not required for one- and two-family dwellings.
Sizes the posts on long balcony runs. Not applied concurrently with the 200 lb.
- Handrail and guard — concentrated1607.9.1.1
200 lb applied in any direction at any point along the handrail or top rail.
- In-fill1607.9.1.2
Balusters, panels and other in-fill: 50 lb horizontal on an area not exceeding 12″ × 12″, including openings and the space between rails, not concurrent with the top-rail loads.
Interior finish and fire performance of wood
Where a hardwood stair goes in a commercial building, the question is which finish class the code assigns to each part. Treads and landings are floor finish; skirts, nosing trim and casing are interior trim; handrails and guards have their own carve-out.
| Item | Requirement | 2021 IBC | UWP note |
|---|---|---|---|
| Treads and landings (floor finish) | Traditional floor finishes such as wood are exempt from the NFPA 253 critical-radiant-flux test that governs floor coverings. | 804.1 exception | Solid hardwood treads are permitted as floor finish in exit stairways. Confirm the sprinkler condition with the architect. |
| Interior trim (skirt board, nosing trim, casing) | Class C minimum — flame-spread index 76–200, smoke-developed ≤ 450 (ASTM E84). | 806.7 | Red oak is the ASTM E84 reference material at FSI 100; the stocked hardwoods fall in Class C untreated. |
| Combustible trim area | Combustible trim may not exceed 10% of the wall or ceiling area of the room — excluding handrails and guards. | 806.7 | |
| Handrails and guards | Excluded from the 10% combustible-trim cap. Wood handrails and guards are permitted in all construction types. | 806.7 · 1014 | |
| Class A or B where required | Where the project spec calls a Class A or B finish on wood, an intumescent or fire-retardant coating with an E84 report is applied after milling. | 803.1.2 | UWP supplies unfinished; the coating is a finisher scope item. Ask for the E84 data before you submit. |
- Treads and landings (floor finish)804.1 exception
Traditional floor finishes such as wood are exempt from the NFPA 253 critical-radiant-flux test that governs floor coverings.
Solid hardwood treads are permitted as floor finish in exit stairways. Confirm the sprinkler condition with the architect.
- Interior trim (skirt board, nosing trim, casing)806.7
Class C minimum — flame-spread index 76–200, smoke-developed ≤ 450 (ASTM E84).
Red oak is the ASTM E84 reference material at FSI 100; the stocked hardwoods fall in Class C untreated.
- Combustible trim area806.7
Combustible trim may not exceed 10% of the wall or ceiling area of the room — excluding handrails and guards.
- Handrails and guards806.7 · 1014
Excluded from the 10% combustible-trim cap. Wood handrails and guards are permitted in all construction types.
- Class A or B where required803.1.2
Where the project spec calls a Class A or B finish on wood, an intumescent or fire-retardant coating with an E84 report is applied after milling.
UWP supplies unfinished; the coating is a finisher scope item. Ask for the E84 data before you submit.
Accessible stairs — ICC A117.1 §504 and 2010 ADA §504
Stairs on an accessible route, and every exit stair in a building that must be accessible, follow §504. The numbers tighten in three places: closed risers, a smaller nosing radius, and handrail extensions.
| Item | Requirement | A117.1 / ADA | UWP note |
|---|---|---|---|
| Risers and treads | Uniform within a flight. Riser 4″–7″; tread 11″ minimum. | 504.2 | |
| Open risers | Not permitted. | 504.3 | |
| Tread surface | Slope not steeper than 1:48 in any direction. | 504.4 | |
| Nosings | Radius of curvature ½″ maximum at the leading edge. Projection 1½″ maximum. Riser may slope under the tread at 30° maximum; the underside of a projecting nosing is angled at 30° maximum. | 504.5 | The ½″ radius is tighter than the IBC 9/16″. Specify the nosing radius explicitly on accessible stairs. |
| Handrails | Both sides, continuous, 34″–38″ high, 1½″ wall clearance, 12″ horizontal extension at the top and one tread depth at the bottom, no sharp or abrasive elements. | 505 |
- Risers and treads504.2
Uniform within a flight. Riser 4″–7″; tread 11″ minimum.
- Open risers504.3
Not permitted.
- Tread surface504.4
Slope not steeper than 1:48 in any direction.
- Nosings504.5
Radius of curvature ½″ maximum at the leading edge. Projection 1½″ maximum. Riser may slope under the tread at 30° maximum; the underside of a projecting nosing is angled at 30° maximum.
The ½″ radius is tighter than the IBC 9/16″. Specify the nosing radius explicitly on accessible stairs.
- Handrails505
Both sides, continuous, 34″–38″ high, 1½″ wall clearance, 12″ horizontal extension at the top and one tread depth at the bottom, no sharp or abrasive elements.
Hardwood stairs that clear the plan check.
Send the stair section, the occupancy and the adopted code year. We return a dimensioned shop drawing with nosing radius, tread depth and rail perimeter called out, so the reviewer reads compliance off the sheet.