Stair Code Library · Handrails

How high should a stair handrail be?

A stair handrail must be between 34″ and 38″ high, measured vertically from the sloped line joining the tread nosings to the top of the rail. The band is the same in the IRC, the IBC and the accessibility standards, and it must be held uniformly along the flight. Fittings — volutes, turnouts, easings, goosenecks — are allowed to rise above 38″ where they make the transition between flights or from rail to guard, and a volute or turnout may sit over the lowest tread.

Reflects 2021 IRC · 2021 IBC · ICC A117.1 · 2010 ADA · 2012 TAS. Adoption is local and amended — confirm the edition your authority having jurisdiction has adopted.

Minimum
34″
Maximum
38″
Measured
Plumb from the nosing line
Fittings
May exceed 38″ at transitions
The rule

Handrail Height

A stair handrail must be between 34″ and 38″ high, measured vertically from the sloped line joining the tread nosings to the top of the rail. The band is the same in the IRC, the IBC and the accessibility standards, and it must be held uniformly along the flight. Fittings — volutes, turnouts, easings, goosenecks — are allowed to rise above 38″ where they make the transition between flights or from rail to guard, and a volute or turnout may sit over the lowest tread.

Residential, commercial and accessible

ItemResidential · IRCCommercial · IBCAccessible · A117.1 / ADA / TAS
Height34″–38″34″–38″34″–38″
Measured fromSloped line of tread nosingsStair tread nosingsStair nosings
UniformAlong the flightAlong the flightConsistent within a flight
Fittings above 38″At transitions, and a volute / turnout / easing over the lowest treadAt transitions—
Guard doubling as handrail34″–38″ on the open side of a stair34″–38″ inside R-2 / R-3 dwelling units only—

Where it is measured

nosing linehandrail 34″–38″plumb from the nosing lineriser 7-3/4″ max (IRC) · 7″ max (IBC)tread depth, nosing to nosing · 10″ min (IRC) · 11″ min (IBC)headroom 6′-8″ (IRC) · 80″ (IBC)plumb from the nosing line to the soffitsoffit / ceilingguard 36″ (IRC) · 42″ (IBC)4″ sphere must not passanywhere in the guard or railingNosing detailprojection 3/4″–1-1/4″radius 9/16″ max · bevel 1/2″ maxSection at 6 px to the inch. Every figure on this drawing is a row in the table above; on the flight the handrail doubles as the open-side guard at 34″–38″.
Riser height is the vertical distance between the walking surfaces of consecutive treads; tread depth is horizontal, nosing to nosing. Handrail and guard heights are measured plumb from the nosing line, headroom plumb from the nosing line to the soffit.

The nosing line, not the tread

Hold a straightedge across the nosings of three or four treads and measure straight up. The rail top must land between 34″ and 38″ above that line at every point. Measuring from the tread surface at the back of the tread reads high by a riser’s worth of slope, which is how a rail that is “36 inches” on site ends up at 33″ over the nosings.

On a landing the guard is measured from the floor, and the residential guard minimum there is 36″; on the rake the guard minimum is 34″. A rail that is both — the top of a guard on the open side of a residential stair — has to be 34″–38″ on the rake and at least 36″ on the landing, which is why the rail steps up at the landing newel.

Setting the rail in wood

On a post-to-post system the rail height is set at the newels: the starting newel is cut so the rail, dropped at the rake angle, lands at the chosen height over the first nosing, and the landing newel so it lands at the same height over the top nosing and at guard height along the balcony. Balusters are then cut to fit between rail and tread. 36″ is the usual target — it leaves an inch of margin either side for a rail that is not perfectly parallel to the nosing line.

On an over-the-post system the rail is continuous and the fittings carry the height change: a starting easing at the bottom, a gooseneck at the landing. Those fittings are the code’s explicit exception to the 38″ maximum.

What 34 to 38 is for

The band comes from where a standing adult’s hand falls: too low and the arm straightens and the grip is lost; too high and the shoulder is raised. Children are served by a second, lower rail where one is provided, which the codes permit but do not require in dwellings. In schools and other places children use, some jurisdictions require a second rail at 28″; the IBC does not.

Cited

The sections, as the tables carry them

These rows are the same rows the full residential and commercial tables show, filtered to this rule. Change one there and it changes here.

Handrails

  • HeightR311.7.8.1

    34″ minimum to 38″ maximum, measured vertically from the sloped line of tread nosings.

    Size baluster length so the rail top lands in the band — the UWP handrail pages list rail thickness.

Guards

  • Height — open side of stairsR312.1.2

    34″ minimum, measured vertically from the nosing line.

    A guard rail at 34″–38″ can double as the stair handrail if it meets the grip rules.

Handrails

  • Height1014.2

    34″ minimum to 38″ maximum above the nosing line, uniform along the flight.

Accessible stairs — ICC A117.1 §504 and 2010 ADA §504

  • Handrails505

    Both sides, continuous, 34″–38″ high, 1½″ wall clearance, 12″ horizontal extension at the top and one tread depth at the bottom, no sharp or abrasive elements.

In hardwood

How the rule is met with the part

Rail thickness is part of the sum. A 6010 profile is about 2¼″ tall, a 6210 a little more, so the underside of the rail — where balusters stop — is 2¼″ below the rail top. Every UWP handrail page lists the section height, and the Handrail & Newel Installation Guide carries the pitch-block method for cutting the newels so the rail lands at 36″ over the nosing line in one pass.

What fails inspection

  1. 01

    Measuring from the tread surface instead of the nosing line.

  2. 02

    A rail set at 34″ exactly. The tolerance is in one direction only; a rail that sags or a nosing line that was drawn optimistically fails. Target 36″.

  3. 03

    A landing guard rail at 34″ because the stair rail was 34″. The landing minimum is 36″.

Questions on this rule

Is 36 inches the code height for a handrail?
36″ is inside the 34″–38″ band and is the height most stairs are built to, because it leaves margin both ways. The code does not name 36″.
Can a handrail be higher than 38 inches?
Only at fittings that make the transition between flights, at winders, or from the rail to a guard, and at a volute, turnout or starting easing over the lowest tread. Along the flight the rail must be at or below 38″.
Does the handrail height change on a commercial stair?
No. 34″–38″ is the same. What changes is that the guard is 42″, so a commercial stair usually has a separate handrail inside the guard rather than a guard whose top is the handrail.
Check it against the part

Send the section. We answer with the part that meets it.

Riser, tread, nosing radius, rail perimeter, extension length — send the stair section and the adopted code year and the shop drawing comes back with each one called out.