How high does a guard have to be?

A residential guard must be at least 36″ high above the floor or landing, and at least 34″ measured from the nosing line along the open side of a stair; where the top of the stair guard is the handrail it must be 34″–38″. A commercial guard is 42″ minimum, with the 36″ and 34″ residential figures kept as exceptions for dwelling units in R-2 and R-3 buildings. Height is measured from the walking surface on floors and plumb from the nosing line on stairs.

Reflects 2021 IRC · 2021 IBC · ICC A117.1 · 2010 ADA · 2012 TAS. Adoption is local and amended — confirm the edition your authority having jurisdiction has adopted.

Residential, floors
36″ min
Residential, stair
34″ min from the nosing line
Commercial
42″ min
Guard as handrail
34″–38″
The rule

Guard Height

A residential guard must be at least 36″ high above the floor or landing, and at least 34″ measured from the nosing line along the open side of a stair; where the top of the stair guard is the handrail it must be 34″–38″. A commercial guard is 42″ minimum, with the 36″ and 34″ residential figures kept as exceptions for dwelling units in R-2 and R-3 buildings. Height is measured from the walking surface on floors and plumb from the nosing line on stairs.

Residential, commercial and accessible

ItemResidential · IRCCommercial · IBCAccessible · A117.1 / ADA / TAS
Floors, landings, balconies36″42″ · 36″ inside R-2 / R-3 dwelling units—
Open side of a stair34″ from the nosing line42″ · 34″ inside dwelling units—
Where the guard top is the handrail34″–38″34″–38″ inside dwelling units only—
Measured fromWalking surface; nosing line on stairsSame—

Where it is measured

42″ · IBC 1015.3 (commercial)36″ from the floor · R312.1.2nosing line34″ min on the rakeplumb from the nosing lineR312.1.2 exc. 1landing newel carries thestep from 34″ to 36″Guard top doubling as the handrail on the rake: 34″–38″ · R312.1.2 exc. 2. The IBC keeps 36″ and 34″ as exceptions inside R-2 / R-3 dwelling units.
One guard, two references: 36″ from the landing floor, 34″ plumb from the nosing line on the rake. The IBC guard is 42″, with the residential figures kept as exceptions inside dwelling units.

Two heights, one guard

The guard along a landing and the guard down the stair are the same run of rail with two references. On the landing it is 36″ off the floor. On the rake it is 34″ off the nosing line — which, because the nosing line is the steepest line on the stair, puts the rail higher than 34″ off the tread everywhere but the nosing. A rail built at 36″ on the rake meets both the guard minimum and the handrail band with margin, and is what most stairs are set to.

The commercial 42 inches

At 42″ a guard is above the centre of gravity of nearly every adult, which is the point of it. Because 42″ is above the 38″ handrail maximum, a commercial stair guard cannot double as the handrail; the handrail is a separate Type I rail on the inside face of the guard at 34″–38″, and the guard top is whatever the design wants. Inside an apartment the residential figures return by exception.

Setting it in wood

The landing newel sets the step from stair height to landing height. On a post-to-post stair a landing newel with the rail entering at 36″ on the rake and 36″ on the level needs the two rail heights to meet at the post, so the landing rail comes in higher on the post than the rake rail; on an over-the-post stair a gooseneck lifts the rail from stair height to landing height in one fitting. Balusters along the balcony are cut for 36″ (42″) less the rail thickness; balusters on the rake are cut to the sloping rail, each one longer than the last by the riser height times the spacing ratio.

Cited

The sections, as the tables carry them

These rows are the same rows the full residential and commercial tables show, filtered to this rule. Change one there and it changes here.

Guards

  • Height — floors and landingsR312.1.2

    36″ minimum above the walking surface.

  • Height — open side of stairsR312.1.2

    34″ minimum, measured vertically from the nosing line.

    A guard rail at 34″–38″ can double as the stair handrail if it meets the grip rules.

Guards

  • Height1015.3

    42″ minimum above the walking surface or nosing line.

    Exceptions: 36″ in R-3 and R-2 dwelling units; 34″–38″ where the top of the guard is the stair handrail.

In hardwood

How the rule is met with the part

Box and turned newels are made in starting and landing heights so the cap clears the rail at 36″ on the rake and on the level, and the Handrail & Newel Installation Guide gives the cut heights for a 36″ rail on a 7½″ × 10″ stair. Iron balusters at 44″ long cover any residential height and most commercial ones after trimming.

What fails inspection

  1. 01

    A landing guard at 34″ because the stair guard was 34″.

  2. 02

    A commercial stair with the 42″ guard top offered as the handrail.

  3. 03

    Measuring the rake guard from the back of the tread, which reads high, and installing it low over the nosings.

Questions on this rule

Is a 36-inch guard enough on a second-floor balcony in a house?
Yes. 36″ above the floor is the IRC minimum for a guard on a floor or landing in a one- or two-family dwelling.
Why is the stair guard lower than the landing guard?
Because it is measured from the nosing line, which is the line a person on the stair stands over. 34″ over the nosings is about the same height relative to the body as 36″ on the flat.
Does a 42-inch guard need a separate handrail?
On a stair, yes. The handrail must be 34″–38″ and graspable, and a 42″ guard top is neither. On a level balcony no handrail is required, only the guard.
Check it against the part

Send the section. We answer with the part that meets it.

Riser, tread, nosing radius, rail perimeter, extension length — send the stair section and the adopted code year and the shop drawing comes back with each one called out.

Terms used on this page