Skip to main content
Unique Wood Products
Looking up an oak stair toward the floor opening and header above, daylight spilling down from the landing
Stair Code Library · Stair geometry

How much headroom does a stair need?

Every part of a stairway needs at least 6′-8″ (80″) of headroom, measured vertically from the sloped line joining the tread nosings — and from the landing surface at landings — to the lowest projection of the ceiling, beam or floor above. The number is the same in the IRC and IBC. Spiral stairs are allowed 6′-6″. Headroom, not width, is what usually decides whether a stair fits in a remodel, because it is set by the floor opening above.

Reflects 2021 IRC · 2021 IBC · ICC A117.1 · 2010 ADA · 2012 TAS. Adoption is local and amended — confirm the edition your authority having jurisdiction has adopted.

Minimum
6′-8″ (80″)
Measured from
The nosing line, plumb
Spiral stairs
6′-6″ (78″)
Floor-opening intrusion
4¾″ max
The rule

Headroom

Every part of a stairway needs at least 6′-8″ (80″) of headroom, measured vertically from the sloped line joining the tread nosings — and from the landing surface at landings — to the lowest projection of the ceiling, beam or floor above. The number is the same in the IRC and IBC. Spiral stairs are allowed 6′-6″. Headroom, not width, is what usually decides whether a stair fits in a remodel, because it is set by the floor opening above.

Residential, commercial and accessible

ItemResidential · IRCCommercial · IBCAccessible · A117.1 / ADA / TAS
Minimum headroom6′-8″80″80″ (307.4 protruding objects)
Measured fromSloped nosing line and landing surfaceSame—
Spiral stairs6′-6″78″—
ExceptionFloor opening may intrude 4¾″ over nosings at the side of the flightDoor hardware / light fixtures within 1011.3—

Where it is measured

soffit✓ headroom 6′-9″✓ 7-1/2″riser✓ tread 10″✓ nosing 1″nosing at 3×
  • Riser height 7-1/2″IRC R311.7.5.1 · 7-3/4″ maxPasses
  • Tread depth 10″IRC R311.7.5.2 · 10″ minPasses
  • Nosing projection 1″IRC R311.7.5.3 · 3/4″–1-1/4″Passes
  • Headroom 6′-9″IRC R311.7.2 · 6′-8″ minPasses

2021 IRC · houses. Checks four numbers on one flight — not uniformity, width, handrails or guards. Your inspector has the final word.

Drawn to scale at 4 px to the inch and redrawn as you set it. Riser height is tread top to tread top; tread depth is horizontal, nosing to nosing; headroom is plumb from the nosing line to the soffit. Limits are the 2021 IRC and IBC rows in the table on this page.

Where it is measured

Draw a line through the tips of the nosings and measure straight up from it. The critical point is nearly always where the flight passes under the header of the floor opening above: the headroom there is the distance from the nosing line to the underside of the finished ceiling at the header, and every riser added to the flight moves that point one tread further down the stair and one riser lower.

The length of the floor opening follows from it. For a 7½″ rise and 10″ run, each tread the opening is shortened costs 7½″ of headroom; to keep 80″ under a 9′ finished floor-to-floor with 12″ of floor structure, the opening has to be roughly 11 treads long — about 9′-2″ — plus the landing at the top.

The 4¾″ exception

Where the treads at the side of a flight run under the edge of the floor opening — a stair with a gallery above and beside it — the IRC lets the floor project horizontally over the nosings by up to 4¾″ into the required headroom. It is a plan dimension, not a height reduction; the 6′-8″ still applies over the walking width.

Remodels

Headroom is the reason a stair cannot simply be moved. A relocated stair needs a floor opening of the right length in the right place, which means cutting joists, and a stair steepened to fit an existing opening runs into the 7¾″ riser limit. Retro-fit treads that add thickness raise the nosing line and reduce headroom by the same amount at the header, which on a stair that was built at 80″ is enough to fail it.

Cited

The sections, as the tables carry them

These rows are the same rows the full residential and commercial tables show, filtered to this rule. Change one there and it changes here.

Stair geometry

  • HeadroomR311.7.2

    6′-8″ (80″) minimum, measured vertically from the sloped line of tread nosings.

  • Spiral stairwaysR311.7.10.1

    26″ minimum clear width; 6¾″ minimum tread depth at a point 12″ from the narrow edge; risers 9½″ maximum; 6′-6″ headroom; all treads identical.

    Pie-shaped treads are milled to the fabricator’s template with the column notch.

Stair geometry

  • Headroom1011.3

    80″ minimum, measured vertically from the nosing line.

In hardwood

How the rule is met with the part

The tread has one effect on headroom: its thickness. A 5/8″ retro-fit tread over an existing stair raises the nosing line ⅝″ less whatever is removed; a 1″ tread over the old treads raises it by the full inch. Where a remodel is tight at the header, that is one more reason the retro-fit profile exists. Nothing in the railing system affects headroom.

What fails inspection

  1. 01

    Measuring headroom from the tread surface at the back of the tread instead of the nosing line. The nosing line is higher, so the true headroom is less.

  2. 02

    Measuring to the joist and forgetting the finished ceiling, or to the drywall and forgetting a beam wrap or a soffit for a duct.

  3. 03

    Adding thickness to the treads on a stair that already sits at 80″.

Questions on this rule

Is 6′-8″ measured at the middle of the stair or the edge?
Everywhere across the walking width. The lowest point above any nosing governs.
Can a beam or duct hang below 6′-8″ over a stair?
Not over the treads or landing. A beam over the landing at 6′-6″ is a headroom failure at the landing, which is measured from the landing surface.
How long does the stair opening need to be?
Long enough that the header clears 80″ above the nosing line. For a typical 7½″ × 10″ stair under a 9′ floor with 12″ of structure, about 9′ plus the landing. The Stair Calculator reports the opening length with the layout.
Check it against the part

Send the section. We answer with the part that meets it.

Riser, tread, nosing radius, rail perimeter, extension length — send the stair section and the adopted code year and the shop drawing comes back with each one called out.

Terms used on this page