Which code editions do Houston, Harris County and Texas enforce?
The City of Houston adopted the 2021 International Codes — IRC, IBC, IEBC, IFC and the rest — by Ordinance 2023-907, passed October 25, 2023 and effective January 1, 2024. The Houston amendments do not alter the IRC stair sections (R311.7, R312) or the IBC stair, handrail and guard sections (1011, 1014, 1015); the one stair-related amendment adds handrail rules for social stairs in assembly occupancies. Unincorporated Harris County requires new houses to meet the IRC edition in force in the county seat and enforces the 2021 IFC and IBC through the Fire Code for commercial work. Accessibility statewide is the 2012 Texas Accessibility Standards under TDLR.
Reflects Houston Ord. 2023-907 · Texas LGC §214 · §233 · 2012 TAS. Adoption is local and amended — confirm the edition your authority having jurisdiction has adopted.
- City of Houston
- 2021 IRC · 2021 IBC
- Effective
- January 1, 2024
- Stair amendments
- None to R311.7, R312, 1011–1015
- Accessibility
- 2012 TAS · TDLR
Houston and Texas Adoption
The City of Houston adopted the 2021 International Codes — IRC, IBC, IEBC, IFC and the rest — by Ordinance 2023-907, passed October 25, 2023 and effective January 1, 2024. The Houston amendments do not alter the IRC stair sections (R311.7, R312) or the IBC stair, handrail and guard sections (1011, 1014, 1015); the one stair-related amendment adds handrail rules for social stairs in assembly occupancies. Unincorporated Harris County requires new houses to meet the IRC edition in force in the county seat and enforces the 2021 IFC and IBC through the Fire Code for commercial work. Accessibility statewide is the 2012 Texas Accessibility Standards under TDLR.
Residential, commercial and accessible
| Item | Residential · IRC | Commercial · IBC | Accessible · A117.1 / ADA / TAS |
|---|---|---|---|
| City of Houston | 2021 IRC with Houston amendments | 2021 IBC with Houston amendments | 2012 TAS, enforced by TDLR |
| Unincorporated Harris County | IRC edition applicable in the county seat (Houston: 2021), per LGC §233.153 | 2021 IBC, through the Harris County Fire Code (2021 IFC), effective January 1, 2025 | 2012 TAS |
| Texas default for municipalities | IRC as it existed May 1, 2012 (LGC §214.212), unless a later edition is adopted | IBC as it existed May 1, 2012 (LGC §214.216), unless a later edition is adopted | 2012 TAS statewide |
What the Houston adoption means on a stair
Because Houston adopted the 2021 editions without amending the stair sections, every number in this library applies inside the city limits as written: 7¾″ risers and 10″ treads in a house, 7″ and 11″ in a commercial building, 36″ and 42″ guards, 34″–38″ handrails, the 4″ sphere. The Houston Residential Code is the 2021 IRC with amendments concentrated in administration, foundations, energy and flood provisions.
The one stair-related amendment is to IBC 1030.16 and concerns social stairs — the wide stepped seating and stair combinations in schools, offices and assembly spaces. Where such a stepped aisle has seating on one side and is 74″ or wider, Houston requires two handrails, one within 30″ of the stepped aisle. The amendment is explained in the Permitting Center’s Technical Memo 17.
Outside the city
Harris County does not operate a residential building department in the way the city does. Texas Local Government Code §233.153 requires new single-family houses and duplexes in the unincorporated area to be built to the IRC — either the 2008 text the statute names or, as the county has elected, the edition in force in the county seat, which is Houston’s 2021 IRC — and §233.154 requires three inspections (foundation, framing, final) by a qualified inspector the builder engages. The county does not inspect; the builder certifies.
Commercial and multifamily construction in the unincorporated area falls under the Harris County Fire Code, enforced by the Fire Marshal, which since January 1, 2025 is based on the 2021 International Fire Code and applies the 2021 IBC to the buildings it covers. The surrounding cities — Sugar Land, Pearland, Katy, Pasadena, The Woodlands under Montgomery County — adopt on their own schedules; ask the city’s building division which edition is in force before you draw.
The Texas statutes behind it
Texas has no state building code. Instead, Local Government Code §214.212 makes the IRC, as it existed on May 1, 2012, the residential building code for every municipality, and §214.216 does the same for the IBC as the commercial code; a city may adopt later editions and local amendments after a public hearing, which is what Houston did. Accessibility is the exception: the Texas Architectural Barriers Act (Government Code Chapter 469) puts it under TDLR statewide, through the Texas Accessibility Standards, and the review is by Registered Accessibility Specialists rather than by the city.
Adopted editions, with sources
Verified September 2026 against the documents linked. Adoption changes; the link is the authority, this table is the summary.
| Jurisdiction | Residential | Commercial | Effective | Source |
|---|---|---|---|---|
| City of Houston | 2021 IRC, Houston amendments | 2021 IBC, IEBC, IFC, Houston amendments | January 1, 2024 (Ord. 2023-907) | Houston Permitting Center — code amendments ↗ |
| City of Houston — stair amendment | None | IBC 1030.16 social stairs: two handrails where a stepped aisle with seating on one side is 74″ or wider | January 1, 2024 | Technical Memo 17 — social stair handrails ↗ |
| Harris County (unincorporated) | IRC as of May 1, 2008 or the edition in force in the county seat; three inspections by a qualified inspector | Harris County Fire Code — 2021 IFC and 2021 IBC for buildings subject to it | Residential standard since September 1, 2009; Fire Code January 1, 2025 | Harris County Fire Code Hub ↗ |
| State of Texas — municipalities | IRC as it existed May 1, 2012 is the municipal residential code unless the city adopts a later edition after a public hearing | IBC as it existed May 1, 2012 is the municipal commercial code on the same terms | Current text effective January 1, 2022 | Texas Local Government Code §214.212 and §214.216 ↗ |
| State of Texas — unincorporated county areas | New single-family and duplex construction to the IRC as published May 1, 2008, or the edition applicable in the county seat | — | Construction begun after September 1, 2009 | Texas Local Government Code §233.153 ↗ |
| State of Texas — accessibility | — | 2012 Texas Accessibility Standards; projects of $50,000 or more registered with TDLR and reviewed and inspected by a Registered Accessibility Specialist | In force | TDLR — 2012 Texas Accessibility Standards ↗ |
How the rule is met with the part
UWP is at 9915 Tanner Road in NW Houston, and most of the stairs it mills are permitted under the Houston Residential Code or the Houston Building Code. When a project is in Fort Bend, Montgomery, Brazoria or Galveston County, or in one of the surrounding cities, send the adopted edition with the drawings and the submittal is checked against that edition’s section numbers.
What fails inspection
- 01
Drawing to the 2015 or 2018 section numbers. The rules are largely the same, but the handrail grip section moved from R311.7.8.3 to R311.7.8.5 in 2018, and a submittal citing the wrong number is sent back.
- 02
Assuming a house in unincorporated Harris County has no code. It has the IRC and three required inspections; it just has no county inspector.
- 03
Pulling the city permit and forgetting TDLR registration on a commercial project over $50,000.
Questions on this rule
- Did Houston change the stair rules when it adopted the 2021 codes?
- No. The Houston amendments to the 2021 IRC leave R311.7 and R312 as published, and the IBC amendments leave 1011, 1014 and 1015 as published. The social-stair handrail amendment to 1030.16 is the only stair-related change.
- Who inspects a new house in unincorporated Harris County?
- A qualified inspector the builder engages — a licensed engineer, a registered architect, a TREC-licensed professional inspector, an ICC-certified residential combination inspector or a building inspector employed by a political subdivision — at foundation, framing and completion, under LGC §233.154.
- Where do I confirm the current edition?
- The Houston Permitting Center’s code-amendment page for the city; the Harris County Fire Code Hub for the county; the city building division for any other municipality. The sources in the table are the ones this page was checked against.
Send the section. We answer with the part that meets it.
Riser, tread, nosing radius, rail perimeter, extension length — send the stair section and the adopted code year and the shop drawing comes back with each one called out.
Questions that come up on these details
What are the IRC stair code rules in plain English?
The IRC residential stair code requires a minimum 10″ tread depth, a maximum 7-3/4″ riser height, a 3/4″ nosing overhang, 36″ minimum stair width, 6′8″ minimum headroom, and handrails on at least one side. Variation between any two treads on the same flight cannot exceed 3/8″. Most code violations on retrofit jobs come from changing the tread thickness without re-framing the stair.
Read the answer →How do I find a stair installer in Houston?
Find a Houston stair installer by asking your hardwood supplier for referrals, checking specific experience with the product family you’re installing (retro-fit, full-build, curved), and confirming licensing, insurance, and finished references. Avoid installers who don’t mention acclimation, can’t explain the skirt-board math, or quote without seeing the stair in person. Ask for 3 finished-stair references in the species and product you’re installing.
Read the answer →