Skip to main content
Unique Wood Products

Lay out the stair, before you build.

RISE & RUN · CODE CHECK · TREAD / RISER / STRINGER FEET

Finished floor to finished floor.

Treads = risers − 1.

Nose-to-nose. Min 10″.

Overhang. ≈ 1″.

Min 36″ residential.

2 typical, 3 if wide.

Stairs: ~10%.

Optional · blended.

Stair — measured elevation
15 risers · 14 treads · 35.8° slope
total run 11.67′total rise 9.00′7.20″ R10″

Rise and run follow your inputs. Depth and finishes are illustrative.

Risers
15
Step count
Riser height
7.20″
Within height limit
Treads
14
11.00″ deep
Total run
11.67′
140.0″ footprint
Stair angle
35.8°
Comfortable
2R + Run
24.4″
Ideal 24–25
Code & comfort check
Riser height
7.20″ · ≤ 7¾″ maximum
OK
Tread run
10.00″ · ≥ 10″
OK
Comfort slope
35.8° · 30° – 37°
OK
Tread stock
42.0 ft
14 × 36″
Riser stock
45.0 ft
15 × 36″
Stringer
29.5 ft
2 × 14.7′
Total material (order)
128.1 ft
Tread + riser + stringer · 10% waste

Treads built to this layout. UWP mills custom stair treads & risers in its core hardwood program — bullnose, pie & winder included.

Browse stair treads →

These are limited dimensional checks, not a complete code review. Common IRC residential limits (riser ≤ 7¾″, run ≥ 10″) apply; confirm local requirements for nosing, headroom, landings, guards and structural support. Visual is scaled and illustrative. Request a quote for an exact mill list.

Reference

Rise, run, and what the code actually requires

How do I calculate stair risers from total rise?
Divide total rise by a riser count until the result lands under the code maximum. 108" over 15 risers is 7.20" each, which passes; over 14 it is 7.71", which also passes but is close to the 7-3/4" ceiling. Always use total finished floor to finished floor — flooring added later is what turns a legal stair into an illegal one.
What are the IRC limits for risers and treads?
For residential stairs the IRC allows a riser of no more than 7-3/4" and requires a tread run of at least 10", measured nose to nose. This calculator checks both and flags a fail. Local amendments vary, so confirm with your jurisdiction before cutting stringers.
Why must all my risers be the same height?
The IRC limits variation between the tallest and shortest riser in a flight to 3/8". People climb stairs by feel, not by looking, so an odd riser is a trip hazard — it is one of the most common failed inspections on a residential stair.
How much total run will my staircase need?
Tread count is one less than riser count, because the upper floor serves as the last tread. Fifteen risers means fourteen treads, and at a 10" run that is 140" of horizontal travel. Check that against the opening before committing to a riser count.
Does the nosing change the tread depth I order?
Unit run is measured nose to nose and is what the code governs. The physical tread is deeper, because the nosing overhangs the riser below — a 10" run with a 1" nosing needs an 11" tread. The calculator reports run for code and tread size for ordering.