Space the balusters so the 4″ ball cannot pass.
COUNT · ON-CENTRE SPACING · CLEAR GAP · IRC R312 / IBC 1015 CHECK
Where
Face of newel to face of newel.
Measured across the widest part that sits in the gap.
Level run — elevation
16 balusters · 3.76″ clear
4.26″ on centre · 3.76″ clear gap. Measured between the inside faces of the newels.
Balusters
16
across 72.0″
On centre
4.26″
first centre 4.01″ from newel
Clear gap
3.76″
under 4″ — passes
Code check
Opening between balusters
3.76″ · < 4″ sphere
Tread / riser / bottom rail triangle
6″ sphere · bottom rail or shoe rail sits low
Lay out to 3-3/4″ clear rather than 4″: a baluster that lands 1/8″ off leaves the gap on the wrong side of the rule. The 6″ triangle is met by the bottom rail height, not by spacing.
Balusters to this count. Iron in Satin Black (four more finishes to order), turned wood in red oak and more — at the Tanner Rd yard.
Browse balusters →The sphere rule is the IRC and IBC requirement as published; adoption is local and amended, so confirm the edition your jurisdiction has adopted. Request a quote for a counted mill list.
Reference
The sphere rule, and how the count is worked out
- What is the 4-inch sphere rule for balusters?
- The IRC (R312.1.3) and the IBC (1015.4) both require that no opening in a guard allow a 4″ sphere to pass. Between balusters that means a clear gap of less than 4″, measured at the widest point of the opening. The trade lays out to 3-3/4″ so a baluster set slightly off still passes.
- How many balusters do I need per tread?
- Divide the tread run by the count and subtract one baluster width: that is the clear gap, because the balusters are vertical and the sphere is tested across the horizontal opening between them. Two 1/2″ iron balusters on a 10-1/2″ run leave 4-3/4″, which fails; three leave 3″, which passes. Two per tread only clears the 4″ rule on short runs or with wide wood balusters, so the calculator reports the minimum per tread for the run entered.
- How do I space balusters evenly on a level run?
- Divide the opening between newel faces so every gap is equal: gap = (opening − balusters × width) ÷ (balusters + 1). Add balusters until the gap is under 4″. The first baluster centre sits one gap plus half a baluster width from the newel face; every centre after it is one gap plus one width further along.
- Does the 4-inch rule apply on the stair as well as the landing?
- Yes. The guard along the open side of a stair is a guard, and the 4″ sphere rule applies between its balusters. Both codes relax it on the stair itself: the IRC (R312.1.3) and the IBC allow a 4-3/8″ sphere on the open side of a stair, while landings and level guards stay at 4″. A separate 6″ sphere rule covers the triangle formed by the tread, the riser and the bottom rail.
- What is the 6-inch triangle rule?
- Where a guard has a bottom rail on a stair, the triangular opening between the tread, the riser and the underside of that rail may not pass a 6″ sphere. It is met by how low the rail or shoe rail sits, not by baluster spacing, which is why this calculator reports it as a rail-height check rather than a count.