Are there commercial or fire-rated stair tread requirements I should know about?
Commercial stair treads in buildings governed by the IBC must meet fire-rating requirements (usually Class A or Class B flame spread), slip-resistance standards, and ADA dimensional rules. Solid hardwood treads can meet most of these requirements with appropriate finish and detailing. Egress stairs in larger commercial buildings often require specific tested assemblies — verify with the project architect or fire marshal before specifying.
The short version
- Fire rating: IBC commercial stairs typically need Class A or Class B flame spread on materials. Solid hardwood with intumescent or fire-rated finish can qualify — verify the specific project.
- Slip resistance: ASTM C1028 or similar — surface coefficient of friction usually ≥ 0.5 dry, ≥ 0.5 wet for stairs.
- ADA dimensions: 11″ minimum tread depth, 4″ to 7″ riser, 12″ handrail extension at top and bottom.
- Egress stairs in larger buildings often require tested fire-rated assemblies — specify only what the architect/fire marshal approves.
The full answer
Commercial stair tread specs are different from residential. The IBC (International Building Code) governs commercial projects in most US jurisdictions (vs. the IRC for residential), and adds requirements around fire rating, slip resistance, ADA compliance, and tested assemblies. Below is the working overview — but always verify with your project architect and the local fire marshal before committing to materials.
Fire rating requirements
Commercial stair treads are typically required to meet flame spread ratings under ASTM E84 testing. The classifications:
- Class A — flame spread index 0–25. The most restrictive. Required in some occupancy types (hospitals, schools, large assembly).
- Class B — flame spread index 26–75. Common in office, retail, and multifamily residential commercial applications.
- Class C — flame spread index 76–200. Lighter requirement; rarely sufficient for commercial stair treads.
Solid hardwood treads can meet Class B and sometimes Class A requirements when:
- Treated with a fire-rated finish — intumescent topcoats are available specifically for fire-rated wood applications.
- Specified species inherently rate well — some species have lower flame spread indexes than others. Brazilian cherry, white oak, and hickory typically perform better than red oak or pine.
- The full assembly is tested — sometimes Class A requires testing the tread + adhesive + substrate as a complete system, not just the wood material.
Slip resistance
Stair treads must provide adequate slip resistance to prevent falls. The standard test is ASTM C1028 (or successor ASTM E303) — surface coefficient of friction. Commercial stair treads typically need:
- Dry coefficient ≥ 0.5 — most matte-finished hardwood meets this.
- Wet coefficient ≥ 0.5 — harder to meet on smooth hardwood; may require slip-resistant additives in the topcoat or applied non-slip strips.
Practical implementations:
- Matte or low-gloss finish rather than high-gloss.
- Aluminum-oxide additive in topcoat for extra slip resistance.
- Applied non-slip strips in the front 4″ of each tread (clear or contrasting; common in transit and institutional applications).
- Roughed or textured wood surface — sometimes specified in heavy-use commercial applications.
ADA dimensional requirements
For accessible commercial stairs (covered by ADA), dimensional requirements are stricter than residential IRC:
- Tread depth: 11″ minimum. Wider than the IRC residential minimum of 10″.
- Riser height: 4″ to 7″. Tighter range than residential 7-3/4″ maximum.
- Uniformity: 3/8″ max variation between any two treads or risers in the same flight.
- Handrail extensions: 12″ horizontal extension beyond the top and bottom nosings (residential is shorter).
- Stair width: 36″ minimum between handrails (same as residential; commercial often requires wider for occupancy load).
- Open risers: generally not permitted on accessible commercial stairs; closed risers required.
- Detectable warnings: sometimes required at the top of stairs in transit and institutional applications.
Egress stairs in larger buildings
Egress stairs — required exit paths in larger commercial buildings — face additional requirements:
- Tested fire-rated assemblies. The whole stair system (treads + risers + skirts + stringer + finish) often needs to be a UL or similar tested assembly. Custom hardwood may not qualify.
- Specific construction materials. Many egress stairs require steel pan stairs with a concrete fill — wood treads can sometimes be applied on top, but the structure underneath is mandated.
- Smoke and fire compartmentalization. The stair enclosure itself must meet fire-rating requirements.
For egress stairs in larger buildings (3+ stories, occupancy above certain thresholds), work directly with the project architect and the fire marshal — these requirements vary by jurisdiction and occupancy classification. Solid hardwood may or may not be permitted depending on the specific stair type and use.
Where solid hardwood works well in commercial
- Small commercial spaces — office suites under occupancy thresholds, small retail, professional offices. Often follow IRC or simpler IBC requirements.
- Hospitality and high-end retail — restaurants, boutiques, design showrooms. Hardwood treads are often a brand asset; the cost and detailing are appropriate.
- Tenant improvement (TI) projects — interior remodels of existing buildings where the stair is not part of egress and not subject to additional commercial code.
- Stair landings and decorative stair sections — the parts of a commercial stair that aren’t egress-mandated often allow hardwood specification.
Where solid hardwood typically doesn’t work
- Multi-story egress stairs. Tested steel-and-concrete assemblies are usually required.
- Schools, hospitals, large assembly. Class A fire ratings are often required and hard to achieve with wood without intumescent treatment.
- Transit, institutional, and high-occupancy buildings. Slip resistance, fire rating, and durability requirements typically point to non-wood materials.
- Industrial applications. Steel grating or non-slip rubber treads typically required.
How to spec correctly for commercial
The standard workflow:
- Confirm occupancy classification with the architect. This determines which code sections apply.
- Identify whether the stair is egress, accessible, or non-essential. Each has different requirements.
- Confirm fire rating requirement — Class A, B, or C — for the tread finish.
- Confirm slip resistance requirement — typically ≥ 0.5 dry, ≥ 0.5 wet.
- Confirm dimensional requirements — ADA may apply.
- Provide manufacturer data to the architect and the fire marshal — they’ll confirm the spec is acceptable before purchase.
UWP and commercial work
UWP regularly supplies stair treads for commercial projects — offices, restaurants, hospitality, retail, and high-end residential. For projects with fire-rating or testing requirements, we work with the architect or fire marshal to specify the correct finish and detail. Commercial projects typically use the same physical tread products as residential — the difference is in the finish (intumescent), the detailing (slip-resistant nosings), and the documentation (test reports, fire ratings).
Bring your project to the Tanner Rd yard with the architect’s specifications. We’ll review the requirements and quote a compliant build.
Related products at UWP
IRC Stair Code Rules
ProductResidential code basics — commercial extends beyond this.
View →Standard Stair Tread Dimensions
ProductTread dimensions for code-compliant builds.
View →Stair Handrail Height
ProductADA accessible stairs need specific handrail extensions.
View →Contractor & Trade Pricing
ProductCommercial project workflow and pricing.
View →Related questions
Terms on this page
Still picking? Email us with the details — stair height, run depth, existing stair condition — and we’ll tell you what we’d actually spec.
Ask the Houston teamPublished 2026-05-27