UWP ANSI A shop drawing sheet for a custom stair tread
Tolerances & material standard

A discipline of tolerances, not taste.

Every figure below is a commitment, not an aspiration — each one is contract language in our guide specification, and each says how it is measured. Hold us to them.

Reflects AWS — Architectural Woodwork Standards · NHLA grading rules. Adoption is local and amended — confirm the edition your authority having jurisdiction has adopted.

How the numbers are checked

Three tolerances and one moisture reading, drawn.

What each figure in the tables below is measured against, and where on the part the measurement is taken.

Length and depthTread in plan, against the cut listlength ± 1/16″depth ± 1/32″within a flightDepth is held step to step: the footnotices the difference, not the absolute.ProfileSection against the drawn template± 1/64″ template band (dashed)Checked against the ground knife andthe drawn section, set-up and first pieces.Moisture at deliveryResistance meter, sample of the lot024681012146–9% MC% moisture contentThe AWS interior range. Re-check on site:the reading that matters is at fixing.Each figure is contract language in the UWP guide specification (06 43 00 and 06 46 00). AWS Custom grade minimum; Premium where scheduled.
Length is measured off the cut against the cut list; tread depth is held across the flight rather than piece by piece; profile is checked against the drawn section on set-up pieces and the first pieces off the machine; moisture is read with a resistance meter on a sample of the lot before it leaves the mill.
Material

Material

What arrives, and the condition it arrives in. Moisture is the figure that decides whether everything downstream holds.

WhatStandardHow it is measured
Moisture content at delivery6–9%Measured with a resistance meter on a sample of the lot before it leaves the mill. Worth re-checking on arrival: material moves in transit and in storage, and the number that matters is the one at the moment it is fixed.
Hardwood gradingNHLA rules; FAS / Select for clear-grade workGraded to the National Hardwood Lumber Association rules, which define permissible character by the yield of clear cuttings. FAS and Select are the top grades and are what clear-grade millwork is cut from.
Paint-grade constructionFinger-jointed, factory primed; joints not visible after finishingFinger joints are inspected after priming. A joint that telegraphs through primer will telegraph through paint, so it is rejected at that point rather than on site.
Fabrication tolerances

Fabrication tolerances

The tolerances the work is held to. These are the numbers behind the claim, and they are the ones to hold us to.

WhatStandardHow it is measured
Profile± 1/64″Checked against the ground knife and the drawn section on set-up pieces before a run, and again on the first pieces off the machine.
Length± 1/16″Measured off the cut against the cut list for the run. Lineal stock is supplied long where a run has to be uninterrupted, because a scarf joint in the middle of a wall is a decision worth making deliberately rather than discovering on site.
Tread depth within a flight± 1/32″Held across the flight rather than piece by piece, because what a foot notices is the difference between one step and the next, not the absolute depth.
SandingTo 150 grit, all faces sealedSealing every face, including the underside and the ends, is what keeps a tread from taking up moisture unevenly and cupping after installation.
Workmanship grade

Workmanship grade

Grade is the vocabulary a millwork specification is written in. Naming one settles a hundred tolerances at once.

WhatStandardHow it is measured
Architectural Woodwork StandardsCustom grade minimum; Premium where scheduledThe AWS defines permitted material characteristics, joinery, machining quality and flatness by grade. Specifying a grade tells the fabricator what is acceptable without the architect having to write out every tolerance.
Fabricator experienceNot less than 10 years milling solid hardwood stair partsStated in the guide specification as a qualification clause, which is where an architect would normally set one.
Installed work

Installed work

Where fabrication tolerance meets code. These are limits on the finished stair rather than on the parts.

WhatStandardHow it is measured
Riser height and tread depth variationNo more than 3/8″ within a flightThis is the code uniformity limit, and it is the one a retrofit most often breaks: an overlay tread raises the walking surface and shortens the top rise.
Handrail height34″–38″ above the nosing line, continuousMeasured vertically from the line touching the tread nosings, not from the floor.
Guard openingsReject a 4″ sphereChecked anywhere in the assembly, including at the base where a shoe rail raises the bottom of the balustrade.
Where these come from

The same numbers, as contract language.

Everything above is drawn from our guide specification. If you are writing a project manual, take it from there rather than retyping it from here — the bracketed choices are already in place.

Specification support

Specifying a project?

Send the drawings and the schedule. We will tell you what we would actually spec, and what we would not.