Skip to main content
Unique Wood Products

Codes & standards

NFPA 253

Also called critical radiant flux, flooring radiant panel test, ASTM E648

The radiant-panel test for floor coverings, which rates a flooring by the heat flux needed to keep it burning.

NFPA 253 (the same method as ASTM E648) lays a flooring sample under an angled radiant panel, ignites one end, and measures the critical radiant flux at which the flame goes out. A higher number means the floor is harder to keep burning. Class I is 0.45 W/cm² or more; Class II is 0.22 to 0.44.

The building code applies it to floor finishes in exits and corridors of certain occupancies, where a wood floor or a wood stair tread is a floor covering in the code’s eyes. Solid hardwood generally meets Class II and often Class I, but the figure has to come from a test report on the material supplied.

It is the floor-covering counterpart of ASTM E84, which rates walls and ceilings. A commercial stair can be asked for both: the tread under one standard, the wall paneling beside it under the other.

On this site

See also

More in codes & standards

Part of the UWP millwork glossary. Milled at the Tanner Rd mill, NW Houston.